Skip to content

LLEAP - simulation software

Plan, run and assess your simulation training

Gain complete control of your simulation training with the Laerdal Learning Application - LLEAP. 

Go to section

Simplicity & control

A single, intuitive interface for all Laerdal simulators

With LLEAP, instructors have control over the patient simulator's physiology, giving a seamless and immersive training experience for the learners. Fully integrated with Laerdal’s simulators, accessory products, Laerdal Scenario Cloud, and SimCapture, LLEAP allows you to control the physiology of the simulator and every other parameter of your training session - both in-situ and in simulation center settings.

Scenario training is easier with LLEAP. Run "on-the-fly", or utilize pre-programmed scenarios for a simple and effective way to run large-scale simulations.

With only one LLEAP PC you can control all LLEAP compatible simulators in your facility.  If you would like an even more mobile solution, you can choose SimPad PLUS

Take your simulation further

  • Choose your LLEAP solution
  • LLEAP simulators
  • Patient Monitoring
  • SimStart - monitor defibrillator
  • LLEAP or SimPad PLUS?
  • Educational Services
  • Technical Services
  • Video Tutorials

Choose your LLEAP solution

3 LLEAP LICENSES: 

LLEAP Standard
A full LLEAP license unifies the control of all PC operated Laerdal simulators and brings simplicity to running simulation training. Includes simulated patient monitor, monitor defibrillator and AED.

LLEAP Fundamentals
LLEAP Fundamentals allows you to conduct training using task trainers and standardized patients with a simulated patient monitor.  

LLEAP Lite
LLEAP Lite is free to download and allows you to practice using LLEAP. Test your scenarios from the comfort of your own PC.

Download LLEAP

LLEAP simulators

Laerdal simulators compatible with LLEAP

  1. SimMan 3G
  2. SimMan 3G Trauma
  3. SimMan ALS
  4. SimMan Essential
  5. SimMom
  6. SimBaby
  7. SimBaby Classic
  8. SimNewB
  9. SimNewB Classic
  10. SimJunior
  11. Nursing Anne Simulator
  12. ALS Simulator
  13. SimMan Classic
  14. SimMan 3G Mystic
  15. SimMan Essential Bleeding

Patient Monitoring

Patient Monitoring with LLEAP

Take simulation to the next level with realistic patient monitoring

The LLEAP platform includes simulated monitoring software as well as a simulated monitor defibrillator/AED.

Give learners an immersive and realistic experience by allowing them to practice on a simulator as well as a patient monitor. It enhances clinical realism and challenges critical thinking skills in all your students. You can also add lab reports, X-Rays and multimedia to enhance the simulation further.

Simulated parameters
LLEAP's patient monitoring capabilities provide concise clinical feedback for physiological parameters, including:

  • ECG
  • SpO2
  • CO2
  • ABP
  • CVP
  • PAP
  • NIBP
  • TOF
  • ..and many more.

SimStart - monitor defibrillator

SimStart - monitor defibrillator

SimStart is a portable and affordable training solution to simulate the use of an AED or a defibrillator monitor. Integrate SimStart with any Laerdal manikin or patient simulator to achieve a more comprehensive and realistic simulation training.

SimStart

SimStart_productOnlyII.JPG

LLEAP or SimPad PLUS?

LLEAP on PC or LLEAP for SimPad? 

Most Laerdal simulators have 2 operating options. Depending on your needs, you can choose to run LLEAP on a PC or on a SimPad PLUS.

LLEAP on PC
  • You can have LLEAP installed on a laptop, tablet, rugged tablet or panel PC to operate your simulator.
  • PC operation is ideal for a use in a control room with multiple training rooms, camera systems and other functionality used by simulation centers. 
  • PC operation supports more advanced functionality compared to SimPad PLUS including additional parameters on the patient monitor, x-ray, multimedia integration, expanded and customized view of the User Interface, and more. 
  • With a PC, you get the ability to integrate third party solutions, such as VitalsBridge patient monitoring and SonoSim ultrasound solutions. 
LLEAP for SimPad PLUS
  • This is a separate version of the LLEAP software. You can use it to control all SimPad PLUS operated manikins and simulators. 
  • SimPad PLUS provides a ‘pick up and play’ user experience.
  • It is portable, and ideal for in-situ training.

Learn more about SimPad PLUS

Educational Services

Educational Services 

Give your instructors knowledge and insights into how to best use the Laerdal products, and enable them to train, motivate and teach students vital lifesaving procedures.

Choose from a range of services and courses - from getting started course and teaching with LLEAP, help to create scenarios, to refresher courses to retain what you've learned. 

Educational Services from Laerdal

Technical Services

Technical Services

Prolong the life-span of your simulation equipment with follow-up services from Laerdal Technical Services. 

We offer comprehensive technical service programs to meet your specific product and training needs. Our Technical Services team can also support the build-out and operation of your clinical lab. With professionally trained technical engineers around the globe, we are here to help.

Technical Services

Video Tutorials

Video tutorials

Watch our video tutorials to help you get started.

LLEAP how-to videos

SimCapture

The best of two worlds

SimCapture is a complete learning management solution for healthcare simulation. It allows you to effectively manage, record, and assess simulation training, both on-site and in-situ.

Capture audio, video, annotations, patient monitors, and simulator data in a single web-based interface.

SimCapture

Overview

Product downloads

User Guides

pdf

SimStart User Guide (3mb)

Simulated AED or Monitor Defibrillator training functionality available in Laerdal Learning Application- LLEAP

Important Information

pdf

Laerdal Network Requirement Document (1mb)

This document describes the requirements for setting up a network on pre-existing infrastructure specifically for Laerdal simulation devices. Replaces LLEAP IT & Network Information document

Software

Session Viewer Downloads

Use this link to download latest software to Session Viewer

SimView Downloads

Use this link to download latest software to SimView

SimView Mobile Downloads

Use this link to download latest software to SimView Mobile

exe

Laerdal Learning Application (LLEAP) v. 6.8.1 (1225mb)

Changes in this release: Simulator lost connection - Improving error message. SimBaby - Improved trachostomy functionality to close Laryngospasm and open airways. SimBaby - Fixed issue with Pharyngeal obstruction not showing in Instructor Application for a virtual simulator. Themes - Now showing features related to available simulator. SimJunior - Fixed issue where simualtor did not show in simulator list. SimMom - Now possible to connect SimMom using Advanced option. LLEAP - Fixed issue related to changeing vital signs before starting session. LLEAP - Fixed issue related to application start. SimMan 3G - Fixed an issue where changes to tracheostoma opening is logged for SimMan 3G which is not supporting it. LLEAP - Fixed an issue where SessionViewer still shows state "Recording" if LLEAP selects to start a new session . Stop compression event - Fixed an issue where stopping simulated compression did not result in a "Stop compression" even.   Changes since 6.8.0: Added support for SimBaby with Tracheostomy. Several improvements and adjustments to UI for SimNewB. Added a Stopwatch function. Click on the time-field next to the Play/Pause button on the Session control window to show the Stopwatch window.. Added a new pre-recorded vocal sound “OK” for Adult(Male/Female) and Child. Improved UI for Stomach distention function. Now have a separate “Release air” button. For SimJunior there is also a separate “Inflate” button. Fixed an issue where LLEAP would sometimes crash when ending a session. Fixed an issue where Tongue fallback was not working properly when running a scenario. Fixed an issue where transitions of User Defined Variables would not always end up on the correct value.

exe

Laerdal Patient Monitor v. 6.8.1 (673mb)

The Laerdal Patient Monitor software is compatible with LLEAP and SimPad. Laerdal Patient Monitor software is included when you download LLEAP. This download allows you to install Laerdal Patient Monitor software without installing LLEAP on the same computer. New version to align with LLEAP 6.8.1 Changes in this release: Defibrillator Monitor - Fixed issue with layout. Patient Monitor Layout - Fixed issue with hidden buttons after minimizing application. Metronom sound - Fixed issue where metronome sound did not start. ECG AV Block - Fixed issue with wrong HR on high heart rates. SimMom - Fixed issue where SimMom was listed twice in simulator list.   Changes since 6.8.0: Simulated AED and Defibrillator monitor (SimStart) now have translated voice prompts. Improved volume indicator on simulated AED/Defibrillator monitor. Fixed an issue where the NIBP auto measurement would be triggered too often. Fixed an issue where the NIBP measurement would sometimes be shown before activating the measurement. Fixed an issue where some buttons would not show after minimizing the Patient Monitor window. Fixed an issue where Patient Monitor in AED mode would sometimes crash.

exe

Laerdal Patient Monitor v. 7.2.0 (911mb)

The Laerdal Patient Monitor software is compatible with LLEAP and SimPad. Laerdal Patient Monitor software is included when you download LLEAP. This download allows you to install Laerdal Patient Monitor software without installing LLEAP on the same computer.   New version to align with LLEAP 7.2.0   Changes in this release: Fixed an issue where the SpO2 vital parameter did not disappear as expected.   Note: Updating to Windows 10? Using SimLink or Custom ad hoc network on SimPad, and considering upgrading to Windows 10 on your computers for Laerdal Patient Monitor? Microsoft ended their support for this type of network with the release of Windows 8. From Windows 10 the equipment will need to use a separate simulation network. Windows 7 By the end of 2020 new releases of LLEAP will no longer support Windows 7

exe

Laerdal Learning Application (LLEAP) v. 7.2.0 (1657mb)

Changes in this release: Changed authentication provider to align with changes in Scenario Cloud. Added an alert for PC or tablet users of Windows 7 as it will no longer be supported for new releases in 2021. Improved discovery of manikins and patient monitors. Improved handling of updates and configuration for SimMan 3G. Fixed an issue where the name of SimMan 3G could not be changed. Fixed an issue where the SpO2 vital parameter did not disappear as expected. Fixed an issue where the "Ok" button would not allow you to proceed in the theme selection dialog. Improved handling of log files for SimMan 3G. Removed Shockwave Flash. General maintenance, bugfixes, and improvements.   Important: Once upgrading to 7.2.0 with Scenario Cloud the organization account is transferred to a new login authentication system and so cannot revert back to 7.1.0 or earlier.   Before installing LLEAP, to secure a successful installation, please make sure the PC is fully updated through Windows Update. If you have problems starting LLEAP after installation, please download and run Visual C++ 2015 redistributable from this location: Microsoft Visual C++ 2015 Redistributable Update 3 . Select and run vc_redist.x86 then try running LLEAP.   Note: Updating to Windows 10? Using SimLink or Custom ad hoc network on SimPad, and considering upgrading to Windows 10 on your computers for Laerdal Patient Monitor? Microsoft ended their support for this type of network with the release of Windows 8. From Windows 10 on, the equipment will need to use a separate simulation network. Laerdal can help you connect all your simulation equipment to a dedicated network. Learn more and get started at Laerdal.com/Network. Windows 7 By the end of 2020 new releases of LLEAP will no longer support Windows 7

exe

LLEAP_7.2.0_Scenario_Cloud_Security_update

This update is needed for LLEAP when using Laerdal Scenario Cloud as of now. Using 7.2 this patch is needed to: Synchronize scenarios Sign in as a Scenario Cloud user Validating the LSC subscription after a 30 day offline period

exe

Laerdal Learning Application (LLEAP) v. 7.3.0 (1526mb)

Important: You may receive a "Windows Defender SmartScreen prevented an unrecognized app from running" Error Message when installing LLEAP. Explanation and how to handle this is explained here: https://laerdal.force.com/HelpCenter/s/article/How-to-handle-error-message-Windows-Defender-SmartScreen-prevented-an-unrecognized-app-from-running.   Changes in this release: New Device Connection Manager (DCM) application to manage network configurations more efficiently on multiple manikins. Enhanced support for Enterprise Network Security from SFNW & for SimMan3G with Wifi USB adapter. Fixed an issue where SimMan3G system time was not synced. Improved simulator connection on networks with high latency. Included WiFi driver to LLEAP installer (for SOM on SimMan3G). Fixed an issue where the simulation wouldn't use the wanted simulation profile unless explicitly selected. Could lead to using wrong units and similar problems. LLEAP supports transport layer security (TLS) 1.2 or greater for login to Scenario Cloud. Fixed an issue causing help files not to work.   Note: Updating to Windows 10? Using SimLink or Custom ad hoc network on SimPad, and considering upgrading to Windows 10 on your computers for Laerdal Patient Monitor? Microsoft ended their support for this type of network with the release of Windows 8. From Windows 10 on, the equipment will need to use a separate simulation network. Laerdal can help you connect all your simulation equipment to a dedicated network. Learn more and get started at Laerdal.com/Network. Last LLEAP version supporting Windows 7 LLEAP 7.3 will be the last version that supports Windows 7. Last version supporting old SimMan 3G family simulators Due to end of life for Windows XP Embedded used on older SimMan3G simulators, LLEAP will no longer supported as of this version, this applies to the following simulators - unless they have been upgraded to use Windows 7: SimMan3G simulators with serial numbers lower than 212-16140000 SimMan3G Essential simulators with serial numbers lower than 213-16140000 SimMan3G Essential Bleeding simulators with serial numbers lower than 214-1614000 Windows Update Before installing LLEAP, to secure a successful installation, please make sure the PC is fully updated through Windows Update. If you have problems starting LLEAP after installation, please download and run Visual C++ 2015 redistributable from this location: Microsoft Visual C++ 2015 Redistributable Update 3. . Select and run vc_redist.x86 then try running LLEAP.

exe

Laerdal PatientMonitor v. 7.3.0 (932mb)

Important: You may receive a "Windows Defender SmartScreen prevented an unrecognized app from running" Error Message when installing LLEAP. Explanation and how to handle this is explained here: How to handle error message "Windows Defender SmartScreen prevented an unrecognized app from running"? .   The Laerdal Patient Monitor software is compatible with LLEAP and SimPad. Laerdal Patient Monitor software is included when you download LLEAP. This download allows you to install Laerdal Patient Monitor software without installing LLEAP on the same computer.   Changes in this release: New version to align with LLEAP 7.3.0 General maintenance, bugfixes and improvements.   Note: Updating to Windows 10? Using SimLink or Custom ad hoc network on SimPad, and considering upgrading to Windows 10 on your computers for Laerdal Patient Monitor? Microsoft ended their support for this type of network with the release of Windows 8. From Windows 10 the equipment will need to use a separate simulation network. Windows 7 Laerdal Patient Monitor 7.3 will be the last version that supports Windows 7

exe

Laerdal Patient Monitor v. 8.0.0 (933mb)

Important: You may receive a "Windows Defender SmartScreen prevented an unrecognized app from running" Error Message when installing LLEAP. Explanation and how to handle this is explained here: How to handle error message "Windows Defender SmartScreen prevented an unrecognized app from running"? .   The Laerdal Patient Monitor software is compatible with LLEAP and SimPad. Laerdal Patient Monitor software is included when you download LLEAP. This download allows you to install Laerdal Patient Monitor software without installing LLEAP on the same computer.   Changes in this release: New version to align with LLEAP 8.0.0 General maintenance, bugfixes and improvements.   Note: Updating to Windows 10? Using SimLink or Custom ad hoc network on SimPad, and considering upgrading to Windows 10 on your computers for Laerdal Patient Monitor? Microsoft ended their support for this type of network with the release of Windows 8. From Windows 10 the equipment will need to use a separate simulation network. Windows 7 Laerdal Patient Monitor 7.3 will be the last version that supports Windows 7

exe

Laerdal Learning Application (LLEAP) v. 8.0.0 (1532mb)

Important: You may receive a "Windows Defender SmartScreen prevented an unrecognized app from running" Error Message when installing LLEAP. Explanation and how to handle this is explained here: https://laerdal.force.com/HelpCenter/s/article/How-to-handle-error-message-Windows-Defender-SmartScreen-prevented-an-unrecognized-app-from-running.   Version 8.0.0 of LLEAP contains the following new functionality: Support for the new SimMan 3G PLUS. New updater for SimMan 3G simulators, providing a more reliable update experience, and improved progress feedback. Support for Nursing Anne Geriatric, allowing Nursing Anne Simulators that are using the new geriatric skin to use geriatric vocal sounds.   In addition, the version contains some important compatibility changes: Link Box Classic will no longer be supported. Running LLEAP on Windows 7 computers will no longer be supported. Older SimMan 3G simulators using Windows XP Embedded will no longer be supported.   Note: Updating to Windows 10? Using SimLink or Custom ad hoc network on SimPad, and considering upgrading to Windows 10 on your computers for Laerdal Patient Monitor? Microsoft ended their support for this type of network with the release of Windows 8. From Windows 10 on, the equipment will need to use a separate simulation network. Laerdal can help you connect all your simulation equipment to a dedicated network. Learn more and get started at Laerdal.com/Network. Windows Update Before installing LLEAP, to secure a successful installation, please make sure the PC is fully updated through Windows Update. If you have problems starting LLEAP after installation, please download and run Visual C++ 2015 redistributable from this location: Microsoft Visual C++ 2015 Redistributable Update 3. . Select and run vc_redist.x86 then try running LLEAP.

exe

LLEAP Patch for 7.3.0, for older SimMAn 3G who can't use LLEAP 8.0 (0.26mb)

This update is supplied to fix an issue where chest rise and lung sounds ceases on the SimMan 3G when used with ASL 5000 using a ventilator setting of PEEP 2 cm H2O or greater. The issue can also be resolved by upgrading to LLEAP 8.0.0. This patch should only be used if upgrade to 8.0.0 is not possible, e.g if using older SimMan 3G with XP embedded which is not supported on LLEAP 8.0.0 and onwards. Important: ASL 5000 plugin needs to be uninstalled before patch installation and reinstalled afterwards. Remember to back up custom lung models when prompted during uninstall process and import again during install process after upgrade to patch.

exe

LLEAP Patch for 7.3.0

LLEAP Patch for 7.3.0, for older SimMAn 3G who can't use LLEAP 8.0   This update is supplied to fix an issue where chest rise and lung sounds ceases on the SimMan 3G when used with ASL 5000 using a ventilator setting of PEEP 2 cm H2O or greater. The issue can also be resolved by upgrading to LLEAP 8.0.0. This patch should only be used if upgrade to 8.0.0 is not possible, e.g if using older SimMan 3G with XP embedded which is not supported on LLEAP 8.0.0 and onwards. Important: ASL 5000 plugin needs to be uninstalled before patch installation and reinstalled afterwards. Remember to back up custom lung models when prompted during uninstall process and import again during install process after upgrade to patch.

Contact us

Request more information

Request more information

What is your preferred contact method
<p>We will handle your personal contact details with care as outlined in <a href="/support/customer-service/privacy-policy/" target="_blank">Laerdal's Privacy Policy</a>.</p>

We will handle your personal contact details with care as outlined in Laerdal's Privacy Policy.

Initiate a Return

Initiate a Return

<p>We will handle your personal contact details with care as outlined in <a href="/support/customer-service/privacy-policy/" target="_blank">Laerdal's Privacy Policy</a>.</p>

We will handle your personal contact details with care as outlined in Laerdal's Privacy Policy.

Technical Service and Support

Technical Service and Support

<p>We will handle your personal contact details with care as outlined in <a href="/support/customer-service/privacy-policy/" target="_blank">Laerdal's Privacy Policy</a>.</p>

We will handle your personal contact details with care as outlined in Laerdal's Privacy Policy.